Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Stomatological Research(Electronic Edition) ›› 2016, Vol. 10 ›› Issue (01): 64-67. doi: 10.3877/cma.j.issn.1674-1366.2016.06.012

Special Issue:

• Dental Nursing • Previous Articles     Next Articles

The design and application of dental equipment cleaning quality check form

Weishu Qi1, Yuzhu Zhou1, Yuena Chen1, Qin Zhan1, Jianzhen Chen1, Liting Lin1,()   

  1. 1. Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
  • Received:2015-07-13 Online:2016-02-01 Published:2016-02-01
  • Contact: Liting Lin
  • About author:
    Corresponding author: Lin Liting, Email:

Abstract:

Objective

To explore the design and application method of quality check form, in order to improve the dental clinic bedside pre-cleaning compliance and dental equipment cleaning quality.

Metheods

Based on the pollution of dental equipment in Hospital of Stomatology of Sun Yat-sen University, the quality check form specific for the dental equipment cleaning was designed and applied to the work of classification, recycling, packaging and checking. According to the data and analysis, corresponding measures were taken to control the influencing factors. Statistical analysis was performed by SPSS 13.0 to compared with the date in November 2012 and November 2012 those after improvement.

Results

The unqualified rate cleaned spatulas was significantly reduced from 7.22% to 2.30% (χ2= 237.50, P<0.001) , whereas that of amalgam pluggers was reduced from 8.29% to 3.09% (χ2= 151.01, P<0.001) ; Dental clinic bedside pre-cleaning unqualified rate of cement pluggers and carbide carvers were both significantly reduced from 10.80% to 3.19% (χ2= 247.70, P<0.001) , and from 8.06% to 2.89% (χ2= 212.31, P<0.001) , respectively.

Conclusions

Dental equipment cleaning quality check form has specialty characteristics and, strong operability, which can provide the basis for the refinement process, revision of quality standards and staff training, as well as improve the bedside pre cleanning compliance, increase the qualified rate of dental equipment cleaning, promoting the continuous improvement of the cleaning quality.

Key words: Dental instrument, Form design, Application, Cleaning

京ICP 备07035254号-28
Copyright © Chinese Journal of Stomatological Research(Electronic Edition), All Rights Reserved.
Tel: 020-87330582 E-mail: zhkqyxyj@163.com
Powered by Beijing Magtech Co. Ltd