Home  About misconduct   中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Stomatological Research(Electronic Edition) ›› 2016, Vol. 10 ›› Issue (01): 17-21. doi: 10.3877/cma.j.issn.1674-1366.2016.01.004

Special Issue:

• Basic Science Research • Previous Articles     Next Articles

Influence of different finishing and polishing techniques on the surface roughness of nanofilled composite resin and adhesion of Streptococcus mutans

Ke Ma1, Yan Gao1,(), Zhongchun Tong1, Xiaoqiong Jiang2, Dongjia Lin1   

  1. 1. Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
    2. Stomatology Health Care Center, Shenzhen Maternity and Child Healthcare Hospital, The Affiliated Hospital of Southern Medical University, Shenzhen 518048, China
  • Received:2015-12-21 Online:2016-02-01 Published:2016-02-01
  • Contact: Yan Gao
  • About author:
    Corresponding author: Gao Yan, Email:

Abstract:

Objective

To investigate the effect of five different polishing systems on the surface roughness of nanofilled composite resin and adhesion of Streptococcus mutans.

Methods

The nanofilled composite resin were selected for this study named Filtek Z350 XT, fifty four specimens were prepared and divided into 6 groups randomly. Five polishing groups specimens were subjected to five different polishing system (OptiDisc, HiLusterPlus, Sof-Lex, Super-snap, Composite Polishing Kit CA0310) treatment, whereas one group received no further surface treatment. Average surface roughness (Ra) were assessed using confocal laser scanning microscope (CLSM) . Then Streptococcus mutans adhered to the 6 groups specimens were cultured in vitro, and the bacterial adhesion amount was measured. ANOVA was used to assess the surface roughness of specimens and the bacterial adhesion amount.

Results

In the five polishing group, the lowest Ra value was obtained in the HiLusterPlus group, except it had lower value than Composite Polishing Kit CA0310 (P= 0.016) , there was no significant difference between the other groups, showing the low surface roughness all. There was no significant difference in bacterial adhesion amount between the five polishing groups, which was lower than that of the non-polishing group (P<0.05) .

Conclusions

The smoothest surface was obtained by Filtek Z350 XT with the use of the polishing system of HiLusterPlus. After polishing systems treatment the amount of the bacteria adhered to nanofilled composites resin decreased significantly.

Key words: Nanofilled composites resin, Polishing, Average surface roughness, Streptococcus mutans, Bacterial adhesion

京ICP 备07035254号-28
Copyright © Chinese Journal of Stomatological Research(Electronic Edition), All Rights Reserved.
Tel: 020-87330582 E-mail: zhkqyxyj@163.com
Powered by Beijing Magtech Co. Ltd