Home  About misconduct   中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Stomatological Research(Electronic Edition) ›› 2014, Vol. 8 ›› Issue (02): 112-117. doi: 10.3877/cma.j.issn.1674-1366.2014.02.005

• Original Articles • Previous Articles    

Shaping efficacy of three instruments in curved root canal preparation

Peilin Zhuang1, Jiantao Ye1, Zhuoshan Huang1, Yansong Yu1, Hong Wu1,()   

  1. 1.Department of Stomatology, Sun Yat-sen Memorial Hospital,Sun Yat-sen University, Guangzhou 510120, China
  • Received:2013-06-30 Online:2014-04-01 Published:2025-02-19
  • Contact: Hong Wu

Abstract:

Objective

To evaluate the shaping efficacy of K files, Safesiders files and HERO Shaper files in curved root canal preparation of human teeth in vitro.

Methods

Sixty mandibular premolars with curved root canal were divided into three groups randomly, and prepared by K files,Safesiders files and HERO Shaper files respectively. Compound meglumine diatrizoate was injected into root canals and X-ray graphs of teeth were taken before and after instrumentation. The amount of dentin removed from inner and outer walls, centering ability and degree of straightening of root canal after preparation were analyzed.

Results

Safesiders files and HERO Shaper files removed less dentin from inner and outer walls than K files at all measuring points (P<0.05). Safesiders files group displayed more dentin removed than HERO Shaper files group, however, the differences were not statistically significant except for the 3 mm and 4 mm measuring points in inner walls (P<0.05). Safesiders files group and HERO Shaper files group showed better centering ability than K files group at measuring points below 5 mm (P<0.05), and differences between Safesiders files group and HERO Shaper files group was not statistically significant (P>0.05). The use of K files resulted in more straightening of root canal after instrumentation compared to other instruments (P<0.05), and the differences between Safesiders files group and HERO Shaper files group was not significant (P>0.05).

Conclusions

K files, Safesiders files and HERO Shaper files caused transportation when preparing curved root canals. Safesiders files and HERO Shaper files showed less transportation and better shaping efficacy.

Key words: NiTi instrument, Root canal preparation, Curved root canal

京ICP 备07035254号-28
Copyright © Chinese Journal of Stomatological Research(Electronic Edition), All Rights Reserved.
Tel: 020-87330582 E-mail: zhkqyxyj@163.com
Powered by Beijing Magtech Co. Ltd