Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Stomatological Research(Electronic Edition) ›› 2015, Vol. 09 ›› Issue (05): 385-389. doi: 10.3877/cma.j.issn.1674-1366.2015.05.006

Special Issue:

• Basic Science Research • Previous Articles     Next Articles

Research of the cytotoxicity of Fe-Ni soft magnetic alloy

Yinhua Xia1, Ermin Nie2, Rui Jiang2, Chunyuan Zhang2,(), Jindi Zeng2, Jizhou Tan2   

  1. 1. Department of Stomatology, Jiangxi Province People′s Hospital, Nanchang 330006, China; Department of Stomatology, First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080, China
    2. Department of Stomatology, First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080, China
  • Received:2015-04-21 Online:2015-10-01 Published:2015-10-01
  • Contact: Chunyuan Zhang
  • About author:
    Corresponding author: Zhang Chunyuan, Email: , Tel: 020-87755766-8404

Abstract:

Objective

To research the cytotoxicity of Fe-Ni soft magnetic alloy in order to provide a biological basis for the clinical application.

Methods

Five groups of materials (Pure Ti, Fe-Ni alloy, Fe-Ni plated Cr6+, Co-Cr alloy, and PVC) were cut into 2 cm × 2 cm × 0.2 cm blocks and prepared for the extract after sterilization. L-929 cells were incubated in five 96-well culture plates at a concentration of 6 × 103 per well for 24 h to allow the attachment. The culture medium was replaced with 100 μl exaction per well. After 1, 2, 3, 4 and 5 d culturing, the cells of each groups were observed under microscope. 10 μl CCK-8 solution was added to each well and cultured for 1.5 h, the absorbance values were obtained with a spectrophotometer. The cytotoxicity of the materials was evaluated by calculating the relative growth rate (RGR) .

Results

The shape of L-929 cells of each group was normal besides the PVC group under the microscope. The cytotoxicity of PVC was grade 3, and all the other materials were grade 0~1 based on the RGR. All of the experimental materials were safe for clinical application except PVC.

Conclusion

Both Fe-Ni alloy and Fe-Ni plated Cr6+ have good biocompatibility.

Key words: Fe-Ni alloy, Plated Cr6+, Cytotoxicity