切换至 "中华医学电子期刊资源库"

中华口腔医学研究杂志(电子版) ›› 2023, Vol. 17 ›› Issue (04) : 265 -271. doi: 10.3877/cma.j.issn.1674-1366.2023.04.006

数字化修复专栏·综述

口腔修复临床诊疗中口颌系统功能评估的数字化实现
蓝凯文, 孙玥, 江柳霖, 阎英()   
  1. 中山大学附属口腔医院,光华口腔医学院,广东省口腔医学重点实验室,广州 510055
  • 收稿日期:2023-06-10 出版日期:2023-08-01
  • 通信作者: 阎英

Digital implementation of functional assessment of the stomatognathic system in prosthodontics

Kaiwen Lan, Yue Sun, Liulin Jiang, Ying Yan()   

  1. Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
  • Received:2023-06-10 Published:2023-08-01
  • Corresponding author: Ying Yan
引用本文:

蓝凯文, 孙玥, 江柳霖, 阎英. 口腔修复临床诊疗中口颌系统功能评估的数字化实现[J]. 中华口腔医学研究杂志(电子版), 2023, 17(04): 265-271.

Kaiwen Lan, Yue Sun, Liulin Jiang, Ying Yan. Digital implementation of functional assessment of the stomatognathic system in prosthodontics[J]. Chinese Journal of Stomatological Research(Electronic Edition), 2023, 17(04): 265-271.

数字化技术已广泛应用于口腔临床实践。口腔修复临床诊疗离不开对患者口颌系统功能的评估,而以往对于患者、咀嚼肌和颞下颌关节的评估存在难以直观分析和客观量化等问题。口腔数字化技术为解决这些难题提供了新途径。本文将以咀嚼肌功能状态评估、力与咬合接触评估及下颌运动功能评估三方面为切入点,探讨数字化技术在口颌系统功能评估中的应用与研究进展,以期为口腔修复临床诊疗的数字化应用提供参考。

Digital technology has been widely used in dental clinical practice. The clinical treatment of prosthodontics is inseparable from the function assessment of the patients′ stomatognathic system. However, the evaluation of occlusion, masticatory muscles, and temporomandibular joints has been difficult to be analyzed in a visualized, objective and quantitative way. Dental digital technology provides new ways to address these challenges. In this article, the digital assessment of masticatory muscle functional status, occlusal force and occlusal contact, and mandibular movement function was taken as the starting point to discuss its application and research progress in stomatognathic system function, so as to provide reference for its application in the clinical prosthodontic treatment.

图1 颞肌前束和咬肌浅层的表面肌电仪检查
图2 T-Scan咬合分析技术的临床应用 A:T-Scan咬合分析仪检查;B ~ C:咬合分析软件中咬合接触的二维、三维图像。
图3 下颌运动超声波描记仪检查
[1]
王美青,谢秋菲,李晓箐,等. [M]. 4版. 北京:人民卫生出版社,2020.
[2]
Chowdhary R, Sonnahalli NK. Clinical applications of the T-Scan quantitative digital occlusal analysis technology a systematic review [J]. Int J Comput Dent2023,0(0):0. DOI:10.3290/j.ijcd.b3945153.
[3]
Ruttitivapanich N, Tansalarak R, Palasuk J,et al. Correlation of bite force interpretation in maximal intercuspal position among patient,clinician,and T-Scan Ⅲ system [J]. Eur J Dent2019,13(3):330-334. DOI:10.1055/s-0039-1693755.
[4]
Nitecka-Buchta A, Nowak-Wachol A, Wachol K,et al. Myorelaxant effect of transdermal cannabidiol application in patients with TMD:A randomized,double-blind trial [J]. J Clin Med2019,8(11):1886. DOI:10.3390/jcm8111886.
[5]
Ayuso-Montero R, Mariano-Hernandez Y, Khoury-Ribas L,et al. Reliability and validity of T-scan and 3D intraoral scanning for measuring the occlusal contact area [J]. J Prosthodont2019,29(1):19-25. DOI:10.1111/jopr.13096.
[6]
Kordaß B, Bernhardt O, Ruge S,et al. Standard and limit values for the symmetry of articulation parameters in the temporomandibular joint area - evaluations of the associated project of the SHIP study [J]. Int J Comput Dent2019,22(4):353-362.
[7]
Woodford SC, Robinson DL, Mehl A,et al. Measurement of normal and pathological mandibular and temporomandibular joint kinematics:A systematic review [J]. J Biomech2020,111:109994. DOI:10.1016/j.jbiomech.2020.109994.
[8]
von der Gracht I, Derks A, Haselhuhn K,et al. EMG correlations of edentulous patients with implant overdentures and fixed dental prostheses compared to conventional complete dentures and dentates:A systematic review and meta-analysis [J]. Clin Oral Implants Res2017,28(7):765-773. DOI:10.1111/clr.12874.
[9]
de Rossi M, Palinkas M, de Lima-Lucas B,et al. Masticatory muscle activity evaluation by electromyography in subjects with zygomatic implants [J]. Med Oral Patol Oral Cir Bucal2017,22(3):e392-e397. DOI:10.4317/medoral.21659.
[10]
Szyszka-Sommerfeld L, Machoy M, Lipski M,et al. The diagnostic value of electromyography in identifying patients with pain-related temporomandibular disorders [J]. Front Neurol2019,10:180. DOI:10.3389/fneur.2019.00180.
[11]
Ebenbichler G, Habenicht R, Blohm P,et al. The back muscle surface electromyography-based fatigue index:A digital biomarker of human neuromuscular aging?[J]. Bioengineering2023,10(3):300. DOI:10.3390/bioengineering10030300.
[12]
Beddis H, Pemberton M, Davies S. Sleep bruxism:An overview for clinicians[J]. Br Dent J2018,225(6):497-501. DOI:10.1038/sj.bdj.2018.757.
[13]
Sônego MV, Goiato MC, Dos Santos DM. Electromyography evaluation of masseter and temporalis,bite force,and quality of life in elderly patients during the adaptation of mandibular implant-supported overdentures [J]. Clin Oral Implants Res2017,28(10):169-174. DOI:10.1111/clr.12980.
[14]
何三纲,于海洋,王美青,等. 口腔解剖生理学[M]. 8版. 北京:人民卫生出版社,2020.
[15]
Qi K, Guo SX, Xu Y,et al. An investigation of the simultaneously recorded occlusal contact and surface electromyographic activity of jaw-closing muscles for patients with temporomandibular disorders and a scissors-bite relationship [J]. J Electromyogr Kinesiol2016,28:114-122. DOI:10.1016/j.jelekin.2016.04.004.
[16]
Nishi SE, Rahman NA, Basri R,et al. Surface electromyography (sEMG) activity of masticatory muscle(masseter and temporalis) with three different types of orthodontic bracket [J]. Biomed Res Int2021:6642254. DOI:10.1155/2021/6642254.
[17]
Mehr K. Surface electromyography in orthodontics—A literature review [J]. Med Sci Monit2013,19:416-423. DOI:10.12659/MSM.883927.
[18]
Nishi SE, Basri R, Alam MK. Uses of electromyography in dentistry:An overview with meta-analysis [J]. Eur J Dent2019,10(3):419-425. DOI:10.4103/1305-7456.184156.
[19]
Lobbezoo F, Ahlberg J, Raphael KG,et al. International consensus on the assessment of bruxism:Report of a work in progress [J]. J Oral Rehabil2018,45(11):837-844. DOI:10.1111/joor.12663.
[20]
Szyszka-Sommerfeld L, Sycińska-Dziarnowska M, Budzynska A,et al. Accuracy of surface electromyography in the diagnosis of pain-related temporomandibular disorders in children with awake bruxism[J]. J Clin Med2022,11(5):1323. DOI:10.3390/jcm11051323.
[21]
Lucas BDL, Barbosa TDS, Pereira LJ,et al. Electromyographic evaluation of masticatory muscles at rest and maximal intercuspal positions of the mandible in children with sleep bruxism [J]. Eur Arch Paediatr Dent2014,15(4):269-274. DOI:10.1007/s40368-014-0111-6.
[22]
Gomes SGF, Custodio W, Faot F,et al. Masticatory features,EMG activity and muscle effort of subjects with different facial patterns [J]. J Oral Rehabil2010,37(11):813-819. DOI:10.1111/j.1365-2842.2010.02075.x.
[23]
Wang XR, Zhang Y, Xing N,et al. Stable tooth contacts in intercuspal occlusion makes for utilities of the jaw elevators during maximal voluntary clenching [J]. J Oral Rehabil2013,40(5):319-328. DOI:10.1111/joor.12044.
[24]
Huang YF, Wang CM, Shieh WY,et al. The correlation between two occlusal analyzers for the measurement of bite force [J]. BMC Oral Health2022,22(1):472. DOI:10.1186/s12903-022-02484-9.
[25]
萧宁,孙玉春,赵一姣,等. 三种数字化分析算法测量咬合接触分布及面积的对比研究[J]. 北京大学学报(医学版)2020,52(1):144-151. DOI:10.19723/j.issn.1671-167X.2020.01.023.
[26]
Morsy N, El Kateb M. In vivo precision of digital static interocclusal registration for full arch and quadrant arch scans:Arandomized controlled clinical trial[J]. BMC Oral Health2022,22(1):559. DOI:10.1186/s12903-022-02612-5.
[27]
王时敏,李峥,王冠博,等. 全程数字化夜磨牙保护垫的制作和初步应用[J]. 北京大学学报(医学版)2019,51(1):105-110. DOI:10.19723/j.issn.1671-167X.2019.01.019.
[28]
Wu ML, Lai PY, Cheong F,et al. Application in the analysis of the occlusal force of free-end missing tooth implant restoration with T-ScanⅢ[J]. Front Bioeng Biotechnol2023,11:1039518. DOI:10.3389/fbioe.2023.1039518.
[29]
Yu W, Chen S, Li X,et al. Evaluation of 1-piece versus 3-piece framework designs for the edentulous mandible with fixed implant-supported prostheses:A clinical,occlusal and biomechanical study [J]. J Prosthodont2021,30(4):290-297. DOI:10.1111/jopr.13320.
[30]
Luo Q, Ding Q, Zhang L,et al. Analyzing the occlusion variation of single posterior implant-supported fixed prostheses by using the T-Scan system:A prospective 3-year follow-up study [J]. J Prosthet Dent2020,123(1):79-84. DOI:10.1016/j.prosdent.2018.12.012.
[31]
Zhang R, Hao X, Zhang K. Evaluation of two different occlusal patterns on single posterior implant-supported crowns:A 12-month prospective study of occlusal analysis[J]. J Prosthet Dent2023. DOI:10.1016/j.prosdent.2022.11.026.
[32]
Prieto-Barrio P, Khoury-Ribas L, Rovira-Lastra B,et al. Variation in dental occlusal schemes two years after placement of single-implant posterior crowns:A preliminary study [J]. J Oral Implantol2022,48(2):110-116. DOI:10.1563/aaid-joi-D-19-00239.
[33]
Canullo L, Tallarico M, Radovanovic S,et al. Distinguishing predictive profiles for patient-based risk assessment and diagnostics of plaque induced,surgically and prosthetically triggered peri-implantitis[J]. Clin Oral Implants Res2016,27(10):1243-1250. DOI:10.1111/clr.12738.
[34]
Di Fiore A, Montagner M, Sivolella S,et al. Peri-implant bone loss and overload:A systematic review focusing on occlusal analysis through digital and analogic methods[J]. J Clin Med2022,11(16):4812. DOI:10.3390/jcm11164812.
[35]
Bandodkar S, Tripathi S, Chand P,et al. A study to evaluate psychological and occlusal parameters in bruxism [J]. J Oral Biol Craniofac Res2022,12(1):38-41. DOI:10.1016/j.jobcr.2021.10.007.
[36]
Zhao Z, Wang Q, Li J,et al. Construction of a novel digital method for quantitative analysis of occlusal contact and force[J]. BMC Oral Health2023,23(1):190. DOI:10.1186/s12903-023-02899-y.
[37]
Adisen MZ, Okkesim A, Misirlioglu M,et al. Does sleep bruxism affect masticatory muscles volume and occlusal force distribution in young subjects?A preliminary study[J]. Cranio2018,37(5):278-284. DOI:10.1080/08869634.2018.1450180.
[38]
Zhao Z, Wang Q, Zheng X,et al. Reliability and validity of two computerised occlusion analysis systems [J]. J Dent2022,118:104051. DOI:10.1016/j.jdent.2022.104051.
[39]
Haralur SB, Majeed MI, Chaturvedi S,et al. Association between preferred chewing side and dynamic occlusal parameters [J]. J Int Med Res2019,47(5):1908-1915. DOI:10.1177/0300060519827165.
[40]
Nota A, Tecco S, Cioffi C,et al. Occlusion time analysis in military pilots affected by bruxism [J]. Sci Rep2019,9(1):1408. DOI:10.1038/s41598-018-38166-2.
[41]
Thumati P, Thumati RP, Poovani S,et al. A multi-center disclusion time reduction (DTR) randomized controlled occlusal adjustment study using occlusal force and timing sensors synchronized with muscle physiology sensors [J]. Sensors2021,21(23):7804. DOI:10.3390/s21237804.
[42]
Wang M, Liu L, Ma X,et al. Computerized dynamic occlusal analysis and its correlation with static characters in post-orthodontic patients using the T-Scan system and the ABO objective grading system [J]. BMC Oral Health2023,23(1):312. DOI:10.1186/s12903-023-02868-5.
[43]
Lin PT, Jiao Y, Zhao SJ,et al. Occlusion and disocclusion time changes in single unit crowns designed by functional generated path technique:A randomised clinical trial [J]. Sci Rep2017,7(1):388. DOI:10.1038/s41598-017-00408-0.
[44]
程明轩,姜婷,孙玉春,等. 比较口内扫描和模型扫描对数字化牙列模型咬合定量分析的影响[J]. 北京大学学报(医学版)2018,50(1):136-140. DOI:10.3969/j.issn.1671-167X.2018.01.023.
[45]
Sigvardsson J, Nilsson S, Ransjö M,et al. Digital quantification of occlusal contacts:A methodological study[J]. Int J Environ Res Public Health2021,18(10):5297. DOI:10.3390/ijerph18105297.
[46]
Okura K, Shigemoto S, Suzuki Y,et al. Mandibular movement during sleep bruxism associated with current tooth attrition [J]. J Prosthodont Res2017,61(1):87-95. DOI:10.1016/j.jpor.2016.06.003.
[47]
周永胜,叶红强. 口腔修复中虚拟患者的构建和应用[J]. 中华口腔医学杂志2022,57(10):997-1002. DOI:10.3760/cma.j.cn112144-20220722-00402.
[48]
Kijak E, Lietz-Kijak D, Frączak B,et al. Assessment of the TMJ dysfunction using the computerized facebow analysis of selected parameters [J]. Biomed Res Int2015:508069. DOI:10.1155/2015/508069.
[1] 吴嘉涵, 尤爱军, 宋燕. 旋后肩法处置肩难产对产妇分娩后盆底肌功能改善的临床研究[J]. 中华妇幼临床医学杂志(电子版), 2021, 17(03): 355-359.
[2] 王焱, 王烟岚. 以始为终:数字化导板在牙列重度磨耗咬合重建序列治疗中的应用[J]. 中华口腔医学研究杂志(电子版), 2023, 17(04): 233-238.
[3] 王勇, 彭玲燕, 赵一姣. 数字化序列导板技术用于"终末牙列"患者即刻种植即刻修复[J]. 中华口腔医学研究杂志(电子版), 2023, 17(04): 239-243.
[4] 张晗之, 丁梦婷, 佘文珺, 焦婷. 骨髓增生异常综合征继发上颌骨坏死患者术后全数字化即刻赝复体制作[J]. 中华口腔医学研究杂志(电子版), 2023, 17(04): 253-259.
[5] 田陶然, 张陶. 数字化虚拟手术设计在口腔种植临床前教学中的应用展望[J]. 中华口腔医学研究杂志(电子版), 2022, 16(03): 189-193.
[6] 李雪铃, 李彦, 滕伟, 古丽莎, 吴湘楠, 阳桂红, 杨凌. 口腔修复学青年教师培训模式的探索[J]. 中华口腔医学研究杂志(电子版), 2022, 16(01): 49-54.
[7] 蓝凯文, 戴驰, 聂嘉祺, 刘俊良, 陈琳灵, 阎英. 牙磨耗评价的临床应用和研究进展[J]. 中华口腔医学研究杂志(电子版), 2021, 15(05): 267-271.
[8] 宾志文, 梁建锋, 王成, 刘海潮, 胡静, 侯劲松. 应用颌间牵引改善数字化下颌骨缺损重建术后咬合不良[J]. 中华口腔医学研究杂志(电子版), 2021, 15(01): 18-23.
[9] 杨够仙, 徐永清. 强化本体感觉训练配合康复路径在膝关节交叉韧带断裂半月板损伤患者术后康复中的应用[J]. 中华老年骨科与康复电子杂志, 2022, 08(03): 165-171.
[10] 马将, 李红, 史万英, 张玉漫, 汪婷, 赵雅彤. 任务导向性训练对上肢周围神经损伤患者肌电图及手功能的影响[J]. 中华老年骨科与康复电子杂志, 2020, 06(03): 159-164.
[11] 吴晓燕, 严凤娣, 殷静静, 於江泉, 郑瑞强. 神经电活动辅助通气和压力支持通气对呼吸衰竭患者呼吸形式的影响[J]. 中华重症医学电子杂志, 2021, 07(02): 120-125.
[12] 廖家权, 吴波, 唐昌敏. 体外冲击波联合肌电生物反馈对脑卒中后足下垂的影响[J]. 中华脑科疾病与康复杂志(电子版), 2023, 13(05): 286-292.
[13] 梁雪琴, 李娜, 潘芳芳, 张香玉, 段亚男. tDCS结合肌电生物反馈对脑梗死后偏瘫老年患者肢体功能、运动功能和动态姿势稳定性的影响[J]. 中华脑科疾病与康复杂志(电子版), 2023, 13(02): 90-96.
[14] 张建萍, 邓海鹏, 焦黛妍, 赵洁. 高频重复经颅磁刺激联合肌电生物反馈治疗脑卒中后吞咽障碍的临床研究[J]. 中华脑科疾病与康复杂志(电子版), 2022, 12(05): 285-290.
[15] 徐浩, 李俊, 吴俊, 王潞. 标准三联术加斜角肌离断治疗侧弯型痉挛性斜颈(附25例报道)[J]. 中华脑科疾病与康复杂志(电子版), 2021, 11(01): 23-26.
阅读次数
全文


摘要