[1] |
|
[2] |
|
[3] |
Noharet R, Pettersson A, Bourgeois D. Accuracy of implant placement in the posterior maxilla as related to 2 types of surgical guides:A pilot study in the human cadaver[J]. J Prosthet Dent,2014,112(3): 526-532. DOI: 10.1016/j.prosdent.2013.12.013.
|
[4] |
Chen Z, Li J, Sinjab K,et al. Accuracy of flapless immediate implant placement in anterior maxilla using computer-assisted versus freehand surgery:A cadaver study[J]. Clin Oral Implants Res,2018,29(12): 1186-1194. DOI: 10.1111/clr.13382.
|
[5] |
Arısan V, Bölükbaşı N, Öksüz L. Computer-assisted flapless implant placement reduces the incidence of surgery-related bacteremia[J]. Clin Oral Investig,2013,17(9): 1985-1993. DOI: 10.1007/s00784-012-0886-y.
|
[6] |
Mazzocco F, Jimenez D, Barallat L,et al. Bone volume changes after immediate implant placement with or without flap elevation[J]. Clin Oral Implants Res,2017,28(4): 495-501. DOI: 10.1111/clr.12826.
|
[7] |
Garcia-Hammaker S, George FM. Use of a surgical template for minimally invasive second-stage surgery:A dental technique[J]. J Prosthet Dent,2019,121(1): 37-40. DOI: 10.1016/j.prosdent.2018.04.013.
|
[8] |
Balshi SF, Wolfinger GJ, Balshi TJ. Surgical planning and prosthesis construction using computer technology and medical imaging for immediate loading of implants in the pterygomaxillary region[J]. Int J Periodontics Restorative Dent,2006,26(3): 239-247. DOI: 10.1038/sj.onc.1209971.
|
[9] |
Turkyilmaz I. Restoring Edentulous Mandible with an Implant-Retained Overdenture in a Day by Means of Flapless Surgery and Stereolithographic Surgical Guide:a Case Report[J]. J Oral Maxillofac Res,2019,10(1): e5. DOI: 10.5037/jomr.2019.10105.
|
[10] |
Fürhauser R, Mailath-Pokorny G, Haas R,et al. Esthetics of flapless single-tooth implants in the anterior maxilla using guided surgery:association of three-dimensional accuracy and pink esthetic score[J]. Clin Implant Dent Relat Res,2015,17 Suppl 2: e427-e433. DOI: 10.1111/cid.12264.
|
[11] |
|
[12] |
张健.数字化口腔种植外科技术[M].沈阳:辽宁科学技术出版社,2016:86-533.
|
[13] |
|
[14] |
Fortin T, Isidori M, Bouchet H. Placement of posterior maxillary implants in partially edentulous patients with severe bone deficiency using CAD/CAM guidance to avoid sinus grafting:a clinical report of procedure[J]. Int J Oral Maxillofac Implants,2009,24(1): 96-102.
|
[15] |
D′haese J, Van De Velde T, Elaut L,et al. A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae[J]. Clin Implant Dent Relat Res,2012,14(2): 293-303. DOI: 10.1111/j.1708-8208.2009.00255.x.
|
[16] |
|
[17] |
Cassetta M. Immediate loading of implants inserted in edentulous arches using multiple mucosa-supported stereolithographic surgical templates:a 10-year prospective cohort study[J]. Int J Oral Maxillofac Surg,2016,45(4): 526-534. DOI: 10.1016/j.ijom.2015.12.001.
|
[18] |
Verhamme LM, Meijer GJ, Bergé SJ,et al. An accuracy study of computer-planned implant placement in the augmented maxilla using mucosa-supported surgical templates[J]. Clin Implant Dent Relat Res,2015,17(6): 1154-1163. DOI: 10.1111/cid.12230.
|
[19] |
Spielau T, Hauschild U, Katsoulis J. Computer-assisted,template-guided immediate implant placement and loading in the mandible:a case report[J]. BMC Oral Health,2019,19(1): 55. DOI: 10.1186/s12903-019-0746-0.
|
[20] |
Verhamme LM, Meijer GJ, Bergé SJ,et al. The use of first stage bone augmentation screws to stabilize the surgical template in the second stage[J]. Int J Oral Maxillofac Surg,2015,44(6): 781-784. DOI: 1016/j.ijom.2015.01.010.
|
[21] |
Lee DH. Strategic Use of Microscrews for Enhancing the Accuracy of Computer-Guided Implant Surgery in Fully Edentulous Arches:A Case History Report[J]. Int J Prosthodont,2018,31(3): 262-263. DOI: 10.11607/ijp.5676.
|
[22] |
|
[23] |
|
[24] |
Lin WS, Yang CC, Polido WD,et al. CAD-CAM cobalt-chromium surgical template for static computer-aided implant surgery:A dental technique[J]. J Prosthet Dent,2019,pii: S0022-3913(19)30295-1. DOI: 10.1016/j.prosdent.2019.04.014.
|
[25] |
|
[26] |
Koop R, Vercruyssen M, Vermeulen K,et al. Tolerance within the sleeve inserts of different surgical guides for guided implant surgery[J]. Clin Oral Implants Res,2013,24(6): 630-634. DOI: 10.1111/j.1600-0501.2012.02436.x.
|
[27] |
El Kholy K, Janner SFM, Schimmel M,et al. The influence of guided sleeve height,drilling distance,and drilling key length on the accuracy of static Computer-Assisted Implant Surgery[J]. Clin Implant Dent Relat Res,2019,21(1): 101-107. DOI: 10.1111/cid.12705.
|
[28] |
Lee DH, An SY, Hong MH,et al. Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery:a prospective clinical study[J]. J Adv Prosthodont,2016,8(3): 207-213. DOI: 10.4047/jap.2016.8.3.207.
|
[29] |
Cristache CM, Gurbanescu S. Accuracy evaluation of a stereolithographic surgical template for dental implant insertion using 3D superimposition protocol[J]. Int J Dent,2017,2017: 4292081. DOI: 10.1155/2017/4292081.
|
[30] |
Bover-Ramos F, Viña-Almunia J, Cervera-Ballester J,et al. Accuracy of Implant Placement with Computer-Guided Surgery:A Systematic Review and Meta-Analysis Comparing Cadaver,Clinical,and In Vitro Studies[J]. Int J Oral Maxillofac Implants,2018,33(1): 101-115. DOI: 10.11607/jomi.5556.
|
[31] |
Vercruyssen M, Laleman I, Jacobs R,et al. Computer-supported implant planning and guided surgery:a narrative review[J]. Clin Oral Implants Res,2015,26 Suppl 11: 69-76. DOI: 10.1111/clr.12638.
|