目的
评价不同暂封材料、暂封方式对根管治疗牙冠方微渗漏的影响,探讨根管治疗牙冠方微渗漏发生情况及与时间的关系。
方法
收集离体牙,常规根管治疗后随机分组,2%亚甲基蓝染色,制作透明样本,体视显微镜下观察样本微渗漏情况,根据染料渗漏最大长度评分,收集数据并进行统计分析。
结果
暂封1、4 周时,Cavit-G 和Caviton 微渗漏评分低于氧化锌丁香酚水门汀(ZOE);暂封2 周,Caviton 微渗漏评分低于ZOE 和Cavit-G。ZOE 作为暂封材料,两种方式样本微渗漏评分比较差异无统计学意义(P >0.05);暂封1 周时,Cavit-G和Caviton 直接与间接暂封微渗漏评分差异无统计学意义(P >0.05),暂封2 周,Cavit-G 和Caviton 微渗漏评分差异无统计学意义(P >0.05)。随暂封时间的延长,3 种材料的微渗漏差异有统计学意义(P <0.05)。
结论
Caviton 冠方暂封效果最好,其次为Cavit-G,ZOE 最差;间接暂封明显加速Cavit-G 和Caviton 暂封样本冠方微渗漏;Caviton 和Cavit-G 用于暂封的适宜时间为2 周,ZOE 为1 周。
Objective
To evaluate the influence of temporary filling materials, filling methods on coronal microleakage of endodontically treated teeth; to discuss the influence of time on the sealing ability of coronal temporary fillings.
Methods
Extracted teeth were randomly divided after treated with root canal therapy.The samples were stained with 2% methylene blue then made clearing specimens.The specimens were evaluated under stereomicroscope and blindly scored for microleakage.The data collected were then analyzed statistically.
Results
Comparison of various sealing materials: the microleakage scores of ZOE were higher than that of Cavit-G and Caviton in 1 week and 4 weeks; whenever in 2 weeks, the microleakage of Caviton was the lowest of the three.Comparison of filling methods: there was no statistically significant difference between the two filling methods of ZOE group (P >0.05).Directly or indirectly sealing for 1 week, the microleakage scores of Cavit-G and Caviton had no statistically significant difference(P>0.05), while there were statistically significant differences when sealing for 2 or 4 weeks (P <0.05).Influence of sealing time: with the proloning of sealing time, the microleakage scores of the three types of materials increased significantly (P <0.05).
Conclusions
Amongst the three materials, Caviton was better than the other two.Usage of cotton pellets increased the coronal microleakage of Cavit-G and Caviton.The optimum time of temporary fillings was 2 weeks for Caviton and Cavit-G, and 1 week for ZOE.