切换至 "中华医学电子期刊资源库"

中华口腔医学研究杂志(电子版) ›› 2019, Vol. 13 ›› Issue (01) : 43 -46. doi: 10.3877/cma.j.issn.1674-1366.2019.01.008

所属专题: 文献

临床研究

正畸患者切牙影像失真发生情况分析
吴志玲1, 刘依2, 曾东林2,(), 崔敏毅2   
  1. 1. 中山大学附属第三医院口腔科,广州 510630
    2. 中山大学光口腔医学院·附属口腔医院,广东省口腔医学重点实验室,广州 510055
  • 收稿日期:2018-07-26 出版日期:2019-02-01
  • 通信作者: 曾东林

Analysis of the incidence and reason of image distortion of incisors of orthodontic patients

Zhiling Wu1, Yi Liu2, Donglin Zeng2,(), Minyi Cui2   

  1. 1. Department of Stomatology, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China
    2. Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
  • Received:2018-07-26 Published:2019-02-01
  • Corresponding author: Donglin Zeng
  • About author:
    Corresponding author: Zeng Donglin, Email:
引用本文:

吴志玲, 刘依, 曾东林, 崔敏毅. 正畸患者切牙影像失真发生情况分析[J]. 中华口腔医学研究杂志(电子版), 2019, 13(01): 43-46.

Zhiling Wu, Yi Liu, Donglin Zeng, Minyi Cui. Analysis of the incidence and reason of image distortion of incisors of orthodontic patients[J]. Chinese Journal of Stomatological Research(Electronic Edition), 2019, 13(01): 43-46.

目的

研究正畸患者曲面体层片上的切牙影像失真发生情况,并分析其原因。

方法

从中山大学附属口腔医院放射科影像数据库中选取500例正畸患者的曲面体层片和头影测量侧位片,所有曲面体层片均采用咬合杆投照,分别从切牙牙体影像放大、缩小、牙根变短、根尖模糊等评价指标分析上下颌切牙影像失真的发生情况,在头影测量侧位片上测量中切牙根尖-对颌切牙切缘的距离,探讨切牙影像失真发生的原因。采用SPSS 19.0统计软件对所得数据进行统计学检验。

结果

500例患者中,切牙牙体影像正常者共417例,切牙牙体影像失真者共83例,影像失真发生率16.6%,其中切牙牙体影像放大17例、牙体影像缩小0例、牙根变短30例,牙根影像变短伴模糊36例。影像失真患者的根尖-切缘距离大于影像正常的患者,差异有统计学意义(F = 5 187.18,P = 0);影像失真患者的覆盖值大于影像正常的患者,差异有统计学意义(F>477,P = 0)。

结论

严重牙颌面畸形如反、深覆盖是导致曲面体层片的切牙影像失真的主要原因之一。

Objective

To study the incidence and reasons of image distortion of incisors on panoramic photography of orthodontic patients.

Methods

The panoramic and cephalometric photography of 500 orthodontic patients were evaluated retrospectively. All of the photography was gotten from the department of radiology, Hospital of Stomatology, Sun Yat-sen University and was taken with bite rod. The image amplifying, shrinking, shortening, and blurring were used as evaluation indicators to analyze the incidence of image distortion of upper and lower incisors. In order to explore the reasons of image distortion, the distance from the root apex of the incisor to the edge of opposite incisor was measured. The One-way ANOVA was used as statistic method to analyze the data with SPSS 19.0.

Results

There were 417 patients who had normal incisor image, and 83 patients with incisor image distortion. The incidence of image distortion was 16.6%. There were 17 patients with amplified incisor image. None of the patient had image shrinking. There were 30 patients with shorten incisor image, and 36 patients with blurred image incisor. The distance from the root apex of the incisor to the edge of opposite incisor of the patients with incisor image distortion was significant greater than the patients with normal incisor image. The One-way ANOVA results shown that the F value was 5 187.18, P value was 0. The overjet of upper and lower incisors of the patients with image distortion was greater than the patients with normal incisor image. The One-way ANOVA results shown that the F value was larger than 477, P value was 0.

Conclusion

Serious dental and maxillofacial malformation such as serious anterior crossbite and deep overjet was one of the main reasons which caused the incisor image distortion on panoramic photography.

图1 前牙反病例曲面体层片
图2 重度深覆盖病例曲面体层片
图3 头影测量侧位片上中切牙根尖-切缘距离示意图 A:正覆盖病例,测量下颌中切牙根尖-切缘距离(LI);B:反病例,测量上颌中切牙根尖-切缘距离(UI)
表1 500例正畸患者根尖-切缘距离测量分析结果(mm, ± s
[1]
傅民魁.口腔正畸学[M]. 6版.北京:人民卫生出版社,2012:9.
[2]
Mckee IW, Glover KE, Williamson PC,et al. The effect of vertical and horizontal head positioning in panoramic radiography on mesiodistal tooth angulations[J]. Angle Orthod,2001,71(6):442-451. DOI:10.1043/0003-3219(2001)071<0442:TEOVAH>2.0.CO;2.
[3]
马绪臣.口腔颌面医学影像学[M]. 6版.北京:人民卫生出版社,2012:9.
[4]
Pawar RR, Makdissi J. The role of focal block(trough/plane)in panoramic radiography:Why do some structures appear blurred out on these images?[J]. Radiography,2014,20(2):167-170. DOI:10.1016/j.radi.2013.11.004.
[5]
Trakiniene G, Šidlauskas A, Švalkauskienė V,et al. The magnification in the lower third and second molar region in the digital panoramic radiographs[J]. J Forensic Dent Sci,2017,9(2):91-95. DOI:10.4103/jfo.jfds_48_16.
[6]
Rondon RH, Pereira YC, do Nascimento GC. Common positioning errors in panoramic radiography:A review[J]. Imaging Sci Dent,2014,44(1):1-6. DOI:10.5624/isd.2014.44.1.1.
[7]
Analoui M. Radiographic image enhancement. Part I:spatial domain techniques[J]. Dentomaxillofac Radiol,2001,30(1):1-9. DOI:10.1038/sj/dmfr/4600562.
[8]
Raitz R, Fenyo-Pereira M, Hayashi AS,et al. Dento-maxillo-facial radiology as an aid to human identification[J]. J Forensic Odontostomatol,2005,23(2):55-59.
[9]
Dhillon M, Raju SM, Verma S,et al. Positioning errors and quality assessment in panoramic radiography[J]. Imaging Sci Dent,2012,42(4):207-212. DOI:10.5624/isd.2012.42.4.207.
[10]
Kaviani F, Johari M, Esmaeili F. Evaluation of common errors of panoramic radiographs in tabriz faculty of dentistry[J]. J Dent Res Dent Clin Dent Prospects,2008,2(3):99-101. DOI:10.5681/joddd.2008.021.
[11]
Razi T, Moslemzade SH, Razi S. Comparison of linear dimensions and angular measurements on panoramic images taken with two machines[J]. J Dent Res Dent Clin Dent Prospects,2009,3(1):7-10. DOI:10.5681/joddd.2009.003.
[12]
Farman AG, Farman TT. Extraoral and panoramic systems[J]. Dent Clin North Am,2000,44(2):257-272,v-vi.
[13]
Kayal RA. Distortion of digital panoramic radiographs used for implant site assessment[J]. J Orthod Sci,2016,5(4):117-120. DOI:10.4103/2278-0203.192113.
[14]
Vazquez L, Nizamaldin Y, Combescure C,et al. Accuracy of vertical height measurements on direct digital panoramic radiographs using posterior mandibular implants and metal balls as reference objects[J]. Dentomaxillofac Radiol,2013,42(2):20110429. DOI:10.1259/dmfr.20110429.
[15]
Sambhana S, Sanghvi P, Mohammed RB,et al. Assessment of sexual dimorphism using digital orthopantomographs in South Indians[J]. J Forensic Dent Sci,2016,8(3):180. DOI:10.4103/0975-1475.195113.
[16]
Khator AM, Motwani MB, Choudhary AB. A study for determination of various positioning errors in digital panoramic radiography for evaluation of diagnostic image quality[J]. Indian J Dent Res,2017,28(6):666-670. DOI:10.4103/ijdr.IJDR_781_16.