中华口腔医学研究杂志(电子版) ›› 2014, Vol. 8 ›› Issue (04) : 286 -290. doi: 10.3877/cma.j.issn.1674-1366.2014.04.004 × 扫一扫
基础研究
收稿日期:
出版日期:
通信作者:
Yanfu Zhou1, Yang Ning1, Junqi Ling1,†()
Received:
Published:
Corresponding author:
周彦夫, 宁杨, 凌均棨. R-Endo 镍钛系统在根管再治疗中的应用[J/OL]. 中华口腔医学研究杂志(电子版), 2014, 8(04): 286-290.
Yanfu Zhou, Yang Ning, Junqi Ling. The efficacy of R-Endo Nickel-Titanium rotary instruments in endodontic retreatment[J/OL]. Chinese Journal of Stomatological Research(Electronic Edition), 2014, 8(04): 286-290.
目的
评价R-Endo 镍钛机用器械在离体牙根管再治疗中的应用性能。
方法
收集根尖孔发育完成的单根管恒牙,根据根管弯曲度分层随机分组。 使用牙胶或RealSeal 树脂充填,而后分别使用Gates-Glidden 钻+K 锉、HERO 642 镍钛机动和R-Endo 镍钛机动再治疗。 记录再治疗时间及从根尖孔推出的碎屑重量,并拍摄术后X 线片,AutoCAD 2008 软件分析残余充填材料与根管壁的面积比。
结果
R-Endo 镍钛系统再治疗时间较长(P=0.003);推出根尖孔碎屑量较Gates-Glidden 钻+K 锉少(P=0.001),与HERO 642 镍钛系统相比差异无统计学意义(P=0.239);根管内残余充填材料与根管壁的面积比低于其他两组,但差异无统计学意义(P=0.157)。 RealSeal 充填组再治疗时间(P=0.001)和推出根尖孔碎屑(P=0.028)均低于牙胶充填组,两者间差异均具有统计学意义(P <0.05)。
结论
R-Endo 机动镍钛系统是根管再治疗的有效方法,其根管清理性能优于手动器械,对根尖周组织激惹度较传统手动器械小,但器械的安全性有待提高。
Objective
To evaluate the efficacy of R-Endo Nickel-Titanium rotary instruments in endodontic retreatment in vitro.
Methods
Extracted caries-free mature single-rooted permanent teeth were collected and divided into 6 groups according to the canal curvature. The teeth were obturated by gutta-percha and RealSeal resin obturation system, and retreated by Gates-Glidden drills. K files, HERO 642 Nickel-Titanium rotary instruments and R-Endo Nickel-Titanium rotary instruments, respectively. The total time of retreatment was recorded, extruded debris was collected and weighed. Moreover, the image of residual filling materials was outlined and measured by AutoCAD 2008 software.
Results
R-Endo system took more operating time than the other 2 methods (P=0.003). And R-Endo system produced significantly less debris extrusion than by Gates-Glidden drill and K file (P=0.001), but there was no significant difference between R-Endo an HERO 642 (P=0.239). Moreover, the mean ratios of remaining fillings versus the area of groups retreated by R-Endo system was lower than other 2 groups, but of no statistically difference (P=0.157). Besides, canals obturated by RealSeal resin obturation system took less operating time (P=0.001) and produced less debris extrusion (P=0.028) than by gutta-percha (P <0.05).
Conclusions
R-Endo Nickel-Titanium rotary system is effective in endodontic retreatment. In comparison with hand instruments, it is more effective in canal wall cleanliness and less irritative to the periapical tissue. But the necessity for improvement on its safety should be recognized.